Features:                                              

  • Supports 9.95 to 11.3Gb/s bit rates
  • Hot-Pluggable
  • Duplex LC connector
  • DWDM TUNABLE laser transmitter
  • APD photo-detector
  • 50GHz ITU-T Grid, C Band
  • SMF links up to 80km
  • 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface
  • Power Supply :+3.3V
  • Power consumption<2.5W
  • Temperature Range: 0~ 70°C
  • RoHS compliant

Applications:
  • Fully Tunable 50GHz DWDM SFP
  • 10GBASE-ZR/ZW Ethernet
  • Sonet OC-192/SDH  SDH STM-64 ITU-T G.959.1 P1L1-2D2
  • 10G Fibre channel
  • DWDM Networks

  • 产品详细信息



RSPD-10GD80-T50
10Gb/s 80km DWDM Tunable SFP Transceiver

Hot Pluggable, Duplex LC, 50GHz ITU-T-T, DWDM Tunable&APD, Single mode



Description:

FIBERWDM’ RSPD-10GD80-T50 Small Form Factor 10Gb/s (SFP) transceivers are compliant with the current SFP Multi-Source Agreement (MSA) Specification. The high performance cooled DWDM TUNABLE transmitter and high sensitivity APD receiver provide superior performance for SONET/SDH, 10G FC and Ethernet applications up to 80km optical links.

The SFP+ Module compliants with SFF-8431, SFF-8432 and IEEE 802.3ae 10GBASE-ZR. Digital diagnostics functions are available via a 2-wire serial interface, as specified in SFF-8472.

The fully SFP compliant form factor provides hot pluggability, easy optical port upgrades and low EMI emission.




  • Absolute Maximum Ratings


Parameter

Symbol

Min.

Typical

Max.

Unit

Storage Temperature

TS

-40

 

+85

°C

Case Operating Temperature

TA

0

 

70

°C

Maximum Supply Voltage

Vcc

-0.5

 

4

V

Relative Humidity

RH

0

 

85

%



  • Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.135 to 3.465 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Note

Supply Voltage

Vcc

3.135

 

3.465

V

 

Supply Current

Icc

 

350

450

mA

 

Power Consumption

P

 

 

1.5

W

 

Transmitter Section:

Input differential impedance

Rin

 

100

 

Ω

1

Tx Input Single Ended DC Voltage Tolerance (Ref VeeT)

V

-0.3

 

4

V

 

Differential input voltage swing

Vin,pp

180

 

700

mV

2

Transmit Disable Voltage

VD

2

 

Vcc

V

3

Transmit Enable Voltage

VEN

Vee

 

Vee+0.8

V

 

Receiver Section:

Single Ended Output Voltage Tolerance

V

-0.3

 

4

V

 

Rx Output Diff Voltage

Vo

300

 

850

mV

 

Rx Output Rise and Fall Time

Tr/Tf

30

 

 

ps

4

LOS Fault

VLOS fault

2

 

VccHOST

V

5

LOS Normal

VLOS norm

Vee

 

Vee+0.8

V

5

Note:

1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.

2. Per SFF-8431 Rev 3.0

3. Into 100 ohms differential termination.

4. 20%~80%

5. LOS is an open collector output. Should be pulled up with 4.7k – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.



  • Optical Parameters(TOP = 0 to 70°C, VCC = 3.135 to 3.465 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Note

Transmitter Section:

Optical Wavelength-End Of Life

λ

X-100

X

X+100

pm

 

Optical Wavelength-Beginning Of Life

λ

X-25

X

X+25

pm

 

Average Optical Power

Pavg

0

 

+5

dBm

1

Laser Off Power

Poff

 

 

-30

dBm

 

Extinction Ratio

ER

6

 

 

dB

 

Transmitter Dispersion Penalty

TDP

 

 

3.0

dB

2

Relative Intensity Noise

Rin

 

 

-128

dB/Hz

3

Optical Return Loss Tolerance

 

20

 

 

dB

 

Receiver Section:

Center Wavelength

λr

1480

 

1565

nm

 

Receiver Sensitivity

Sen

 

 

-23

dBm

4

Los Assert

LOSA

-40

 

-

dBm

 

Los Dessert

LOSD

 

 

-24

dBm

 

Los Hysteresis

LOSH

0.5

 

 

dB

 

Overload

Sat

-7

 

 

dBm

5

Receiver Reflectance

Rrx

 

 

-12

dB

 

Note:

1. Average power figures are informative only, per IEEE802.3ae.

2. TWDP figure requires the host board to be SFF-8431compliant. TWDP is calculated using the Matlab code provided in clause 68.6.6.2 of IEEE802.3ae.

3. 12dB reflection.

4. Conditions of stressed receiver tests per IEEE802.3ae. CSRS testing requires the host board to be SFF-8431 compliant.

5. Receiver overload specified in OMA and under the worst comprehensive stressed condition.

 


  • Timing Characteristics

Parameter

Symbol

Min.

Typical

Max.

Unit

TX_Disable Assert Time

t_off

 

 

10

us

TX_Disable Negate Time

t_on

 

 

1

ms

Time to Initialize Include Reset of TX_FAULT

t_int

 

 

300

ms

TX_FAULT from Fault to Assertion

t_fault

 

 

100

us

TX_Disable Time to Start Reset

t_reset

10

 

 

us

Receiver Loss of Signal Assert Time

TA,RX_LOS

 

 

100

us

Receiver Loss of Signal Deassert Time

Td,RX_LOS

 

 

100

us

Rate-Select Chage Time

t_ratesel

 

 

10

us

Serial ID Clock Time

t_serial-clock

 

 

100

kHz

 


  • Pin Assignment

Diagram of Host Board Connector Block Pin Numbers and Name

 

 

 

 

  • Pin Function Definitions

PIN #

Name

Function

Notes

1

VeeT

Module transmitter ground

1

2

Tx Fault

Module transmitter fault

2

3

Tx Disable

Transmitter Disable; Turns off transmitter laser output

3

4

SDL

2 wire serial interface data input/output (SDA)

 

5

SCL

2 wire serial interface clock input (SCL)

 

6

MOD-ABS

Module Absent, connect to VeeR or VeeT in the module

2

7

RS0

Rate select0, optionally control SFP+ receiver. When high, input data rate >4.5Gb/ s; when low, input data rate <=4.5Gb/s

 

8

LOS

Receiver Loss of Signal Indication

4

9

RS1

Rate select0, optionally control SFP+ transmitter. When high, input data rate >4.5Gb/s; when low, input data rate <=4.5Gb/s

 

10

VeeR

Module receiver ground

1

11

VeeR

Module receiver ground

1

12

RD-

Receiver inverted data out put

 

13

RD+

Receiver non-inverted data out put

 

14

VeeR

Module receiver ground

1

15

VccR

Module receiver 3.3V supply

 

16

VccT

Module transmitter 3.3V supply

 

17

VeeT

Module transmitter ground

1

18

TD+

Transmitter inverted data out put

 

19

TD-

Transmitter non-inverted data out put

 

20

VeeT

Module transmitter ground

1

Note:

1. The module ground pins shall be isolated from the module case.

2. This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board.

3. This pin shall be pulled up with 4.7K-10Kohms to VccT in the module.

4. This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board.



  • SFP Module EEPROM Information and Management

The SFP modules implement the 2-wire serial communication protocol as defined in the SFP -8472. The serial ID information of the SFP modules and Digital Diagnostic Monitor parameters can be accessed through the I2C interface at address A0h and A2h. The memory is mapped in Table 1. Detailed ID information (A0h) is listed in Table 2. And the DDM specification at address A2h. For more details of the memory map and byte definitions, please refer to the SFF-8472, “Digital Diagnostic Monitoring Interface for Optical Transceivers”. The DDM parameters have been internally calibrated.



Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)

 

 



Table 2 - EEPROM Serial ID Memory Contents (A0h)

Data Address

Length

(Byte)

Name of

Length

Description and Contents

Base ID Fields

0

1

Identifier

Type of Serial transceiver (03h=SFP)

1

1

Reserved

Extended identifier of type serial transceiver (04h)

2

1

Connector

Code of optical connector type (07=LC)

3-10

8

Transceiver

10G Base-ZR

11

1

Encoding

64B/66B

12

1

BR, Nominal

Nominal baud rate, unit of 100Mbps

13-14

2

Reserved

(0000h)

15

1

Length(9um)

Link length supported for 9/125um fiber, units of 100m

16

1

Length(50um)

Link length supported for 50/125um fiber, units of 10m

17

1

Length(62.5um)

Link length supported for 62.5/125um fiber, units of 10m

18

1

Length(Copper)

Link length supported for copper, units of meters

19

1

Reserved

 

20-35

16

Vendor Name

SFP vendor name: FIBERWDM

36

1

Reserved

 

37-39

3

Vendor OUI

SFP transceiver vendor OUI ID

40-55

16

Vendor PN

Part Number: “TSPLXG80D-T50” (ASCII)

56-59

4

Vendor rev

Revision level for part number

60-62

3

Reserved

 

63

1

CCID

Least significant byte of sum of data in address 0-62

Extended ID Fields

64-65

2

Option

Indicates which optical SFP signals are implemented

(001Ah = LOS, TX_FAULT, TX_DISABLE all supported)

66

1

BR, max

Upper bit rate margin, units of %

67

1

BR, min

Lower bit rate margin, units of %

68-83

16

Vendor SN

Serial number (ASCII)

84-91

8

Date code

FIBERWDM’s Manufacturing date code

92-94

3

Reserved

 

95

1

CCEX

Check code for the extended ID Fields (addresses 64 to 94)

Vendor Specific ID Fields

96-127

32

Readable

FIBERWDM specific date, read only

128-255

128

Reserved

Reserved for SFF-8079

 


  • Digital Diagnostic Monitor Characteristics

Data Address

Parameter

Accuracy

Unit

96-97

Transceiver Internal Temperature

±3.0

°C

98-99

VCC3 Internal Supply Voltage

±3.0

%

100-101

Laser Bias Current

±10

%

102-103

Tx Output Power

±3.0

dB

104-105

Rx Input Power

±3.0

dB



  • Regulatory Compliance

The TSPLXG80D-Dxx complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards (see details in Table following).

 

Electrostatic Discharge

(ESD) to the Electrical Pins

MIL-STD-883E

Method 3015.7

Class 1(>1000 V)

Electrostatic Discharge (ESD)

to the Duplex LC Receptacle

IEC 61000-4-2

GR-1089-CORE

Compatible with standards

Electromagnetic

Interference (EMI)

FCC Part 15 Class B

EN55022 Class B (CISPR 22B)

VCCI Class B

Compatible with standards

Laser Eye Safety

FDA 21CFR 1040.10 and 1040.11

EN60950, EN (IEC) 60825-1,2

Compatible with Class 1 laser

product.



  • Recommended Circuit

 

 

Recommended Host Board Power Supply Circuit

 

 

 

 

Recommended High-speed Interface Circuit

 

 

  • Mechanical Dimensions

 

 

  •  Order Information:  


RSPD-10GD80-T50                 XX: 50GHz ITU-T Grid Wavelength

Channel Value

Frequency (THZ)

Central Wavelength(nm)

ITU Channel

1

191.95

1561.83

19.5

2

192

1561.42

20

3

192.05

1561.01

20.5

4

192.1

1560.61

21

5

192.15

1560.2

21.5

6

192.2

1559.79

22

7

192.25

1559.39

22.5

8

192.3

1558.98

23

9

192.35

1558.58

23.5

10

192.4

1558.17

24

11

192.45

1557.77

24.5

12

192.5

1557.36

25

13

192.55

1556.96

25.5

14

192.6

1556.55

26

15

192.65

1556.15

26.5

16

192.7

1555.75

27

17

192.75

1555.34

27.5

18

192.8

1554.94

28

19

192.85

1554.54

28.5

20

192.9

1554.13

29

21

192.95

1553.73

29.5

22

193

1553.33

30

23

193.05

1552.93

30.5

24

193.1

1552.52

31

25

193.15

1552.12

31.5

26

193.2

1551.72

32

27

193.25

1551.32

32.5

28

193.3

1550.92

33

29

193.35

1550.52

33.5

30

193.4

1550.12

34

31

193.45

1549.72

34.5

32

193.5

1549.32

35

33

193.55

1548.91

35.5

34

193.6

1548.51

36

35

193.65

1548.11

36.5

36

193.7

1547.72

37

37

193.75

1547.32

37.5

38

193.8

1546.92

38

39

193.85

1546.52

38.5

40

193.9

1546.12

39

41

193.95

1545.72

39.5

42

194

1545.32

40

43

194.05

1544.92

40.5

44

194.1

1544.53

41

45

194.15

1544.13

41.5

46

194.2

1543.73

42

47

194.25

1543.33

42.5

48

194.3

1542.94

43

49

194.35

1542.54

43.5

50

194.4

1542.14

44

51

194.45

1541.75

44.5

52

194.5

1541.35

45

53

194.55

1540.95

45.5

54

194.6

1540.56

46

55

194.65

1540.16

46.5

56

194.7

1539.77

47

57

194.75

1539.37

47.5

58

194.8

1538.98

48

59

194.85

1538.58

48.5

60

194.9

1538.19

49

61

194.95

1537.79

49.5

62

195

1537.4

50

63

195.05

1537

50.5

64

195.1

1536.61

51

65

195.15

1536.22

51.5

66

195.2

1535.82

52

67

195.25

1535.43

52.5

68

195.3

1535.04

53

69

195.35

1534.64

53.5

70

195.4

1534.25

54

71

195.45

1533.86

54.5

72

195.5

1533.47

55

73

195.55

1533.07

55.5

74

195.6

1532.68

56

75

195.65

1532.29

56.5

76

195.7

1531.9

57

77

195.75

1531.51

57.5

78

195.8

1531.12

58

79

195.85

1530.72

58.5

80

195.9

1530.33

59

81

195.95

1529.94

59.5

82

196

1529.55

60

 

 

 

 



想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
10G SFP+  Transceiver 10G DWDM SFP+ Optical Transceiver
10G SFP+ optical transceiver module, support 10Gb/s and up to 100 km transmission, including: SFP+ SR, SFP+ LR, SFP+ ER, SFP+ ZR, etc. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on.
10G SFP+  Transceiver 10G SFP+ Optical Transceiver
10G SFP+ optical transceiver module, support 10Gb/s and up to 100 km transmission, including: SFP+ SR, SFP+ LR, SFP+ ER, SFP+ ZR, etc. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on.
10G SFP+  Transceiver 10G CWDM SFP+ Optical Transceiver
10G SFP+ optical transceiver module, support 10Gb/s and up to 100 km transmission, including: SFP+ SR, SFP+ LR, SFP+ ER, SFP+ ZR, etc. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on.
10G SFP+  Transceiver 10G BIDI SFP+ Optical Transceiver
10G SFP+ optical transceiver module, support 10Gb/s and up to 100 km transmission, including: SFP+ SR, SFP+ LR, SFP+ ER, SFP+ ZR, etc. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on.
10G SFF DWDM ZR 10G DWDM SFF 40km Transceiver -40℃ To 85℃
Features 1550nm or DWDM EML Laser with TEC,Available in all C‐Band Wavelengths on the 50GHz PIN- TIAReceiver LC duplex connector or customizable pigtail fiber Single Channel+ 3.3V Power Supply The CDR off-line mode supports 155-9.95 GBIT/s bit rate, and the CDR mode supports 9.95-10.3125 GBIT/s bit rate Internal Transmitting/Receiving CDR -40℃ to 85℃ Working Industria Temperature Suitable for40km SMF connection Comply with SFF-8472 Rev 10.2 Whole Metal Shell and Excellent electromagnetic interference performance Completely comply with RoHS Standard
10G SFP+  Transceiver XFP 10G 1310nm 10km Transceiver
Features: Support multi protocol from 9.95Gb/s to 11.3Gb/s Hot pluggable 30 pin connector Compliant with XFP MSA Transmission distance of 10km over Single mode fiber 1310nm DFB laser transmitter. Duplex LC connector 2-wire interface for management and diagnostic monitor XFI electrical interface with AC coupling Single power supply voltages: +3.3V Temperature range 0°C to 70°C Power dissipation: <1.5W RoHS Compliant Part Applications: 10GBASE-LR/LW Ethernet SONET OC-192 /SDH 1200-SM-LL-L 10G Fiber Channel Other optical links Transceiver Types:
10G SFP+  Transceiver XFP 10G 1550nm 40km Transceiver
Features: Support multi protocol from 9.95Gb/s to 11.3Gb/s Hot pluggable 30 pin connector Compliant with XFP MSA Transmission distance of 40km over single mode fiber Cooled EML laser transmitter. Duplex LC connector 2-wire interface for management and diagnostic monitor XFI electrical interface with AC coupling Power supply voltages: +3.3V, +5V Temperature range 0°C to 70°C Power dissipation: <3W RoHS Compliant Part Applications: 10GBASE-ER/EW Ethernet SONET OC-192 IR-2/SONET OC-192 IR-3/SDH STM S-64.2b/SDH STM S-64.3b 40km 10G FC Other optical links Transceiver Types:
10G XFP Transceiver XFP 10G 1550nm 80km Transceiver
Features: Support multi protocol from 9.95Gb/s to 11.3Gb/s Hot pluggable 30 pin connector Compliant with XFP MSA Transmission distance of 80km over single mode fiber Cooled EML laser transmitter. APD Receiver Duplex LC connector 2-wire interface for management and diagnostic monitor XFI electrical interface with AC coupling Power supply voltages: +3.3V, +5V Temperature range 0°C to 70°C Power dissipation: <3.5W RoHS Compliant Part Applications: 10GBASE-ZR/ZW Ethernet SONET OC-192 / SDH STM-64 ITU-T G.959.1 P1L1-2D2 80km 10G FC Other optical links Transceiver Types:
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系